arXiv:2603. 03312v3 Announce Type: replace-cross Abstract: Decoding natural language from non-invasive EEG signals is a promising yet challenging task.
By Yuchen Wang, Haonan Wang, Yu Guo, Honglong Yang, Xiaomeng Li
EEG-Captioner introduces a new EEG-to-language framework that grounds language generation in measurable EEG signal properties. The authors built a large dataset of 160,781 EEG segments annotated with question‑answer pairs targeting spectral, spatial, temporal, and lateral properties, and paired each segment with a feature‑grounded caption. Their Dual‑Domain EEG Encoder jointly models temporal waveforms and spectral‑spatial representations, achieving a macro‑averaged balanced accuracy of 88.81% on signal‑level QA and improving caption factual consistency from 82.06% to 83.46% compared to caption‑only models.
By Leyuan Jin, Jiahao Mei, Yixuan Yuan, Shimeng Li, Mengyue Wu, Yue Ding
The paper introduces BraVista, a visual-language framework that transforms multichannel EEG signals into structured images and uses instruction‑conditioned vision‑language models for unified multi‑task EEG decoding. By continuing post‑training of a general‑domain VLM, BraVista adapts to neural signals without large‑scale EEG‑specific pretraining, achieving strong performance across sleep staging, emotion recognition, cognitive workload classification, and abnormal EEG detection. Analyses show that the EEG‑to‑image representation is crucial and that the model’s performance degrades gradually with added noise, indicating reliance on genuine EEG information.
By Parastoo Azizeddin, Omid Sharafi, Maryam M. Shanechi
EEG-to-Report is a browser-based annotation and feature‑text framework that links routine EEG review with the creation of AI‑ready datasets. It ingests multi‑format EEG data, standardizes channels, and provides an interactive viewer with a multimodal annotation layer that combines typed text and transcribed voice notes. For each annotated segment, a feature extraction engine computes standardized spectral, temporal, entropy, Hjorth, connectivity, and spike‑related descriptors, stored alongside clinical descriptions in a portable JSON schema, producing aligned feature‑text pairs for training multimodal EEG‑language models. The framework also includes an auto‑report module that uses an ensemble of convolutional networks and a large language model to draft clinical narratives for neurologist review, thereby streamlining annotation workflows and enabling editable draft reports.
By Xuan-The Tran, Le Trung Kien Nguyen
arXiv:2603. 17109v2 Announce Type: replace Abstract: Decoding brain activity into natural language is a major challenge in AI with important applications in assistive communication, neurotechnology, and human-computer interaction.
By Akshaj Murhekar, Christina Liu, Abhijit Mishra, Shounak Roychowdhury, Jacek Gwizdka
ProCA: Progressive Contrastive Alignment for Robust EEG Visual Decoding introduces a model‑agnostic framework that adaptively aligns EEG signals with visual semantics. It replaces fixed visual or textual anchors with EEG‑aware class‑level contrastive supervision and employs structure‑consistent interpolation to preserve channel‑wise and temporal importance. Across multiple evaluation settings—including subject‑dependent, subject‑independent, strict cross‑subject transfer, and continual adaptation—ProCA delivers significant performance gains, achieving relative Top‑1 improvements ranging from 7.4% to 28.1%.
By Kanglei Zhou, Chunyan Lan, Dongyang Li, Jun Zhu, Liyuan Wang
arXiv:2605.27790v2 Announce Type: replace
Abstract: Recent advances in large language models have accelerated open-vocabulary EEG-to-imagined-text decoding, where non-invasive neural activity recorde...
By Akshaj Murhekar, Abhijit Mishra
The paper introduces AttrEcho, a framework that enhances EEG-to-image retrieval by incorporating explicit visual attributes aligned with spatial regions of pretrained vision encoders. AttrEcho uses Region-Aligned Visual Attribute Fusion (RAVF) to merge EEG-relevant local attributes with pretrained features via a learnable gate, and Feature Token Aggregation (FTA) to weight and aggregate these refined features for contrastive alignment with EEG signals. Experiments on the THINGS-EEG dataset show that AttrEcho achieves high retrieval accuracy, outperforming baseline methods in both intra- and inter-subject scenarios.
By Ke Xiao, Banghua Yang, Wenbin Guo, Fenqi Rong
This survey reviews recent advances in converting non‑invasive EEG signals into images, text, and audio using generative AI techniques such as GANs, VAEs, transformers, and diffusion models. It summarizes datasets, feature‑encoding methods, evaluation metrics, and key challenges, noting that EEG‑to‑image models mainly use encoder‑decoder architectures, EEG‑to‑text leverages transformer language models, and EEG‑to‑audio maps signals to mel‑spectrograms for vocoder synthesis. The paper highlights the limitations of small, heterogeneous datasets, poor cross‑subject generalization, and the lack of standardized benchmarks, while providing open‑source resources to support reproducible research.
By Shreya Shukla, Jose Torres, Akshaj Murhekar, Christina Liu, Abhijit Mishra, Jacek Gwizdka, Shounak Roychowdhury
arXiv:2605.23137v3 Announce Type: replace-cross
Abstract: Electroencephalography (EEG) visual decoding remains challenging due to the modality gap between low-SNR neural signals and highly structured...
By Jiahe Meng, Weiming Zeng, Yueyang Li, Bo Chai, Hongjie Yan, Zhiguo Zhang, Wai Ting Siok, Nizhuan Wang
arXiv:2608.21445v1 Announce Type: new
Abstract: Automated seizure detection from electroencephalography (EEG) is essential for continuous neurological monitoring, particularly for subclinical epilept...
By Chenxi Liu, Mingzhao Li, Yicong Liu, Hao Miao, Hongyuan Zhang, Ziyi Chen, Gaofeng Meng
The paper presents a reproducible single‑subject baseline for reconstructing visual stimuli from EEG using a temporal‑spatial convolutional encoder that maps averaged EEG signals to 512‑dimensional ViT-B/32 image features. On the THINGS‑EEG2 dataset, the model achieves 12.83%, 39.17%, and 58.00% image recall at ranks 1, 5, and 10, respectively, outperforming analytical chance levels. The study also shows that performance drops sharply when applying a model trained on one subject to others, and that direct conditional generators without external visual weights produce noise‑dominated outputs, indicating that only coarse semantic decoding is feasible under the tested protocol.
By Harshit Goyal