arXiv AI

Cross-Modality Investigation on WESAD Stress Classification

The paper presents transformer models trained on the WESAD dataset to detect stress from various physiological signals—ECG, EDA, EMG, RESP, TEMP, and ACC—achieving state‑of‑the‑art accuracy, precision, and recall between 99.73% and 99.95%. It evaluates both single‑modality and cross‑modality performance, visualizing learned embeddings in 2D and analyzing data variance to explain cross‑modal behavior. The study is among the first to interpret embedding spaces for stress detection, offering insights into model robustness across modalities.

arXiv Machine Learning
Sep 21

From Stress to Affect: Multimodal Deep Learning for Physiological Emotion Recognition Across Wearable Sensor Modalities

The study compares temporal deep learning models—Bidirectional LSTM, Temporal Convolutional Network, and Transformer—for physiological emotion recognition using two multimodal wearable datasets, WESAD and EmoWear. Experiments evaluate wrist-only, chest-only, and multimodal sensor configurations with participant-independent leave-one-subject-out cross-validation, and also explore ensembles, sensor ablation, sampling frequency, and saliency analysis. Results show that the best architecture varies by dataset, multimodal sensing consistently outperforms single-site configurations, and a 4 Hz sampling rate offers a cost-effective operating point.

By Desta Haileselassie Hagos, Saurav Keshari Aryal, Legand L. Burge
arXiv Machine Learning
Oct 5

LiteEMG-FM: An Efficient and Deployable Foundation Model for Robust EMG Sensing

LiteEMG-FM is an efficient hybrid CNN‑Transformer foundation model designed for electromyography (EMG) sensing. It is pretrained on 16 diverse upper‑ and lower‑limb EMG datasets, enabling representations that generalize across users and datasets. The model incorporates a lightweight, always‑on 1D‑CNN wake‑up module that filters rest and non‑target activity, activating LiteEMG‑FM only for valid gestures, and is evaluated in full inference offloading, split inference, and full on‑device processing scenarios, showing superior performance over state‑of‑the‑art time‑series foundation models and supervised baselines, especially in zero‑calibration cross‑participant and data‑scarce conditions.

By Tianhao Wu, Xu Wu, Amirmohammad Radmehr, Jiawei Yu, Yi Wu, Phuc Nguyen, Jian Liu
arXiv Machine Learning
Sep 15

Bridging the Gap in ECG-Based Emotion Recognition: A Unified Evaluation of Deep Learning Models

The paper evaluates deep learning models for electrocardiogram‑based emotion recognition, focusing on generalization across datasets rather than dataset‑specific performance. It introduces two open‑source tools—ARRC for standardized benchmarking and ARDT for inter‑dataset training—to merge three public AER datasets (CUADS, ASCERTAIN, DREAMER) into a more variable benchmark. Using these tools, the authors compare three prominent deep learning architectures and two CNN baselines with hyperparameter tuning and 10‑fold cross‑validation, revealing trade‑offs between accuracy and model complexity and providing a reproducible benchmark for future research.

By Timothy C Sweeney-Fanelli, Ajan Ahmed, Masudul Imtiaz
arXiv Machine Learning
Jun 26

State-Specific Respiratory Signatures for Affective and Stress Recognition: Interpretable Respiratory Markers, Autocorrelation Lags, and Compact CNN Models

arXiv:2606. 26723v1 Announce Type: cross Abstract: Respiratory activity is a direct and interpretable physiological channel for wearable stress and affective-state recognition, yet many studies emphasize classification accuracy without identifying which respiratory properties separate different states.

By Andrei Velichko, Mehmet Tahir Huyut
Hugging Face Trending Papers
Jun 22

Deep learning-based detection of cessation of breathing in pre-term infants

Apnoea of prematurity is characterised by recurrent episodes of cessation of breathing and remains difficult to detect reliably using routinely monitored physiological signals in the Neonatal Intensive Care Unit (NICU). Existing bedside monitors rely primarily on respiratory rate and oxygen saturation thresholds, often generating high false-positive alarm rates and missing short or irregular events.